General Purpose Laboratory Centrifuges

General Purpose Laboratory Centrifuges

Product Details:

  • Display Type LED / Analog
  • Features Automatic lid lock, balanced rotor, anti-vibration feet
  • Control Type Digital / Analog knob
  • Power Supply AC Mains, 50 Hz
  • Speed Range Up to 5000 RPM
  • Accuracy Speed 2%
  • Temperature Resistance Up to 40C operating temperature
  • Click to View more
X

General Purpose Laboratory Centrifuges Price And Quantity

  • 1 Unit
  • 56 dB(A)
  • Yes, lid interlock mechanism
  • 3500 g
  • 0-60 min mechanical timer
  • Epoxy powder coated for durability
  • Stainless steel inner chamber for corrosion resistance
  • Approximately 18 kg
  • Various tube adapters available
  • Fixed angle rotor supplied, swing-out rotor optional

General Purpose Laboratory Centrifuges Product Specifications

  • AC Mains, 50 Hz
  • Steel body with powder coated finish
  • Benchtop Centrifuge
  • Up to 5000 RPM
  • 220-240 V AC
  • LED / Analog
  • Digital / Analog knob
  • Metal
  • Automatic lid lock, balanced rotor, anti-vibration feet
  • Lab
  • General Purpose Laboratory Centrifuge
  • 510 x 410 x 330 mm (approx.)
  • Different Available
  • Rectangular
  • General Purpose Laboratory Centrifuges
  • Up to 40C operating temperature
  • 370 W
  • 6 x 15 ml or 8 x 15 ml or 12 x 15 ml
  • Speed 2%
  • Yes
  • 56 dB(A)
  • Yes, lid interlock mechanism
  • 3500 g
  • 0-60 min mechanical timer
  • Epoxy powder coated for durability
  • Stainless steel inner chamber for corrosion resistance
  • Approximately 18 kg
  • Various tube adapters available
  • Fixed angle rotor supplied, swing-out rotor optional

General Purpose Laboratory Centrifuges Trade Information

  • Cash in Advance (CID)
  • 50 Unit Per Month
  • 7 Days
  • All India

Product Description

With Centrifuge Medical & Institutional laboratories can obtain better performance than ever before available with a centrifuge of this type. Special features include :
  • Easy lid lock stepless speed regulator Safety Fuse, Elegant front panel. With wide choice of rotor heads and adaptors. this unit is truly versatile This centrifuge is available in a choice of 2 models.
  • The R-8c has additional digital speed meter and timer.
  • Now available for special applications : The centrifuge model R c has now been made more verstaile and suitable for the following special application.
  • T.B. Tests in Hospital : Mac Cartney Test Bottles used for T.B. Tests can now be directly centrifuged .

Specification

Max. Speed

RPM

5250

MAX. rcf

g.

3600

Max. Capacity

ml

ml 3200

WXDXH

mm

365 X 410 X 315

 




Efficient & Customizable Laboratory Separation

This centrifuge offers flexibility for numerous laboratory procedures with interchangeable fixed-angle and swing-out rotors. The precise speed control (2% accuracy), timer (0-60 min), and a selection of adapters for different tube volumes enhance usability for diverse protocols, making it a reliable asset for research, diagnostics, and industrial labs.


Uncompromised Safety and Durability

Safety features such as a mechanical and lid interlock mechanism, automatic lid lock, and anti-vibration feet uphold operator protection. The stainless steel chamber resists corrosion, while the powder-coated exterior provides an extra layer of resilience and ease of maintenance, ensuring sustained performance in demanding environments.

FAQ's of General Purpose Laboratory Centrifuges:


Q: How do I operate the general purpose laboratory centrifuge safely?

A: To operate safely, always load tubes symmetrically, select the desired speed and timer settings using the digital or analog controls, and ensure the chamber lid is closed. The automatic lid lock and interlock mechanism prevent the centrifuge from running if the lid is open.

Q: What types of rotors and tubes are compatible with this centrifuge?

A: A fixed angle rotor is supplied as standard, while an optional swing-out rotor is available. The centrifuge accommodates various tube adapters and supports capacities of 6, 8, or 12 tubes of 15 ml each, offering flexibility for different applications.

Q: Where is the centrifuge most commonly used?

A: This benchtop centrifuge is widely used in general laboratory settings, including clinical, research, and industrial labs, thanks to its adaptable design, reliable performance, and robust build.

Q: When should I use the mechanical timer versus digital controls?

A: Choose the mechanical timer for simple, repeatable timing between 0-60 minutes. Digital controls are preferred when precision timing and speed accuracy (2%) are required for more sensitive protocols.

Q: What benefits does the stainless steel chamber offer?

A: The stainless steel inner chamber provides excellent corrosion resistance, increasing the instrument's lifespan and allowing easy cleaning, which is essential for maintaining laboratory hygiene and compliance.

Q: How does the safety interlock system enhance user safety during operation?

A: The built-in safety interlock and automatic lid lock ensure that the lid remains securely closed during operation, preventing accidental opening, exposure to spinning rotors, or sample ejection.

Q: What maintenance steps should I follow for optimal performance?

A: Regularly clean the stainless steel chamber and tube adapters with mild detergents, inspect the rotor for balance and wear, and verify that all safety mechanisms are functioning before each use. Following these steps maintains performance and increases the life of the centrifuge.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number