Microprocessor Based Flame Photometer

Microprocessor Based Flame Photometer

Product Details:

  • Power Supply AC Mains
  • Features Automatic zero and sensitivity adjustment, flame out detection, Na/K filter selection switch, built-in compressor
  • Glass Type Borosilicate glass nebulizer
  • Shape Rectangular
  • Accuracy 2% of full scale
  • Control Type Microprocessor Control
  • Display Type 4 Digit, 7 Segment LED Display
  • Click to View more
X

Microprocessor Based Flame Photometer Price And Quantity

  • 1 Unit
  • 4-5 ml/min
  • Continuous as well as batch
  • RS232 interface for data output
  • Na, K, Ca, Li filter sets included
  • High efficiency, corrosion resistant
  • 0 - 100 ppm
  • Built-in, noise-free blower type
  • 0 - 100 ppm
  • 2 ppm minimum
  • 0 - 100 ppm
  • Stainless steel body with propane/LPG gas use
  • Direct aspiration
  • 1 ppm minimum
  • Digital, direct concentration in ppm
  • Microprocessor based, automatic with curve fitting
  • 0 - 100 ppm
  • Yes, automatic cut-off
  • Flame monitoring, gas leakage detection, auto shutdown

Microprocessor Based Flame Photometer Product Specifications

  • AC Mains
  • Yes
  • Metal
  • 230 V
  • Lab
  • Borosilicate glass nebulizer
  • Digital Flame Photometer
  • Microprocessor Based Flame Photometer
  • Automatic zero and sensitivity adjustment, flame out detection, Na/K filter selection switch, built-in compressor
  • Powder coated steel body
  • Rectangular
  • Microprocessor Based Flame Photometer
  • 220 Volt (v)
  • 4 Digit, 7 Segment LED Display
  • Upto 50C operating temperature
  • 410 x 260 x 265 mm
  • 2% of full scale
  • Microprocessor Control
  • 4-5 ml/min
  • Continuous as well as batch
  • RS232 interface for data output
  • Na, K, Ca, Li filter sets included
  • High efficiency, corrosion resistant
  • 0 - 100 ppm
  • Built-in, noise-free blower type
  • 0 - 100 ppm
  • 2 ppm minimum
  • 0 - 100 ppm
  • Stainless steel body with propane/LPG gas use
  • Direct aspiration
  • 1 ppm minimum
  • Digital, direct concentration in ppm
  • Microprocessor based, automatic with curve fitting
  • 0 - 100 ppm
  • Yes, automatic cut-off
  • Flame monitoring, gas leakage detection, auto shutdown

Microprocessor Based Flame Photometer Trade Information

  • Cash in Advance (CID)
  • 50 Unit Per Month
  • 7 Days
  • All India

Product Description

An ideal instrument for the determination od Sodium Potassium, Calcium and Lithium. it uses the latest Microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The System has 3 point calibration facility using curve fitting software. It has soft touch membrane keys for ease of operation. The solution is aspirated through an atomiser. Air, sample and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. The color of the flame is changed depending upon the concentration of elements present. Radiations from the flame passes through the sensing system and specific narrow band interference filter which permits only the characteristic radiation to pass to the photodetector. The output of the photo-detector is then processed by the microcontroller and the final results are displayed on the digital display.

Specification 

Specifications

 

 

 

Range

PPm

Meq/l

Serum Urine

Na : 0.1 to 100

0.435-435

0.87-870

K : 0.1 to 100

0.256 - 256

0.512-512

Ca : 15 to 100

Li : 0.5 to 100

.724-144.8

 

Sensitivity

0.1 ppm

Accuracy

+/- 1 % up to 40 ppm

+/- 2 % above 40 ppm

Readout

5 digit seven segment bright red LED display

Flame system

LPG & dry oil free air

Detector

Photodiode

Calibration

3 point calibration

Power

230V+/- 10% AC, 50Hz

Weight

8 Kg (Approx)

Air Supply

By oil free mini compressor unit with pressure regulator

Combustion gas

LPG

ATOMISER

Axial flow type

Burner

Stainless Steel

Standard Accessories

Sample Holder ( 5 No.s) Dust Cover, Mains Lead Chimney,

Capillary Tubes (3 No.s) Air and Gas Tubing alongwith End

Clamps (1 Set), Cleaning Wire, Instruction Manual



Precision Measurement & Versatile Applications

With measurement ranges for Na, K, Ca, and Li up to 100 ppm and a sensitivity of as low as 1 ppm, this flame photometer is ideal for laboratories needing accurate elemental analysis. The stainless steel burner, high-efficiency nebulizer, and microprocessor-based control provide reliable results across various lab settings, ensuring consistent and trustworthy data for research, quality control, and teaching purposes.


Advanced Safety & User-Friendly Features

Safety is paramount, with flame monitoring, gas leakage detection, and automatic shut-off integrated into the design. The built-in, noise-free compressor and straightforward operation - including automatic zero and sensitivity adjustment - simplify measurement routines. Direct aspiration, batch or continuous modes, and intuitive controls make it an ideal choice for demanding laboratory environments.


Reliable Output & Data Management

The digital readout displays concentration values in ppm on a bright LED screen, and an RS232 interface allows seamless data export for recordkeeping and analysis. Robust construction with a powder-coated steel body and borosilicate glass nebulizer ensures durability, while easy calibration and maintenance minimize downtime. Designed for use across India, this equipment meets industry standards for accuracy and reliability.

FAQ's of Microprocessor Based Flame Photometer:


Q: How does the microprocessor-based calibration improve measurement accuracy in this flame photometer?

A: The inbuilt microprocessor provides automatic calibration using curve fitting, ensuring accurate and reliable results by minimizing human error and compensating for instrument drift each time a measurement is performed.

Q: What elements can be measured with this photometer, and what are their sensitivity levels?

A: This instrument measures Sodium (Na), Potassium (K), Calcium (Ca), and Lithium (Li) within a 0-100 ppm range for each element. It offers a minimum sensitivity of 2 ppm for Na and 1 ppm for K, ensuring detection of low concentrations with high precision.

Q: When should the flame photometer be recalibrated during operation?

A: Recalibration is recommended whenever a new sample set is analyzed, after lengthy operations, or if accuracy appears to be drifting. The automatic calibration function simplifies this process, enabling quick and precise setup for each analysis session.

Q: Where can this flame photometer be used and what materials is it constructed from?

A: This photometer is suitable for laboratory use throughout India and internationally. Its housing is made from powder-coated steel, with a stainless steel burner and borosilicate glass nebulizer, offering durability and resistance to laboratory conditions.

Q: What is the process for introducing samples and how does the equipment ensure accurate aspiration?

A: Samples are introduced via direct aspiration at a rate of 4-5 ml/min, using a high-efficiency, corrosion-resistant nebulizer that ensures a uniform spray for consistent and accurate readings.

Q: How are safety and operational benefits provided to users?

A: Safety features include flame monitoring, gas leakage detection, automatic flame failure cut-off, and auto shutdown. Operational benefits include automatic zero and sensitivity adjustment, digital readout, filter selection switches, and seamless data output for user convenience.

Q: What are the main advantages of using this flame photometer for laboratory analysis?

A: Key benefits include high measurement accuracy, rapid results, robust safety features, easy calibration and maintenance, versatility for batch or continuous operation, and reliable data management. Its sturdy design and warranty support further enhance its value for labs.